5 Repair
5.6.1 Replacing the axis-1 joint unit (CRB 15000-5/0.95)
Continued
Removing the swing (-5/0.95)
1
2
3
Loosening the base and removing the base cover
1
Continues on next page
780
Action
Remove the swing attachment screws.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
Use two fully threaded attachment screws as re-
moval tools to press the swing out of position.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
Lift away the swing.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
Action
Loosen the base from the foundation by removing
the attachment screws and washers.