ABB CRB 15000 Product Manual page 313

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

2
3
4
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Fit the protection plate to the drive board unit.
Tip
Using the protection plate is important for protect-
ing the drive board unit. If complete joint unit is
to be replaced, the protection plate is not needed.
Cut the cable tie at the drive board.
Remove the protection plate.
© Copyright 2021 - 2023 ABB. All rights reserved.
5.3.3 Replacing the axis-2 cabling
Note
Protection plate: 3HAC077790-001
(for CRB 15000-5/0.95) /
3HAC087789-001 (for CRB 15000-
10/1.52 and CRB 15000-12/1.27)
xx2000002057
xx2000002058
xx2100000301
Continues on next page
5 Repair
Continued
313