5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
2
3
4
5
6
7
Continues on next page
1020
Action
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the tubular
mounting surface, as pointed out in the figure.
Lift the tilt into mounting position while inserting
the cabling into the tubular.
Slide the tilt into place on the guide pins.
Secure the tilt to the tubular with all attachment
screws but two.
Pre-tighten the screws crosswise firstly.
Remove the guide pins and fasten the remaining
two screws.
Torque tighten all screws crosswise.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000002147
xx2000002131
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111 (14 pcs)
xx2000002130
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111 (2 pcs)
xx2000002128
Tightening torque: 1.8 Nm.