5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
6
7
Removing the axis-5 cover
1
2
Continues on next page
994
Action
Remove the joint unit from the tubular.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Remove the lifting aid and guide pins.
Action
Remove the cover by removing the four screws.
CAUTION
Valid for CRB 15000-5/0.95
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2000002169
Position shown in the figure shows
axis 5 jogged to +20°, which is a
more convenient position when re-
placing only the axis-6 joint unit.
xx2000001957
Note
xx2000002132
Product manual - CRB 15000
3HAC077389-001 Revision: L