5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
2
3
4
Continues on next page
1012
Action
Fit the lifting aid to the joint unit.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Fit two guide pins to the joint unit.
Place the cabling at the slot before refitting the
joint unit.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Joint unit: 3HAC079143-001 (for
CRB 15000-5/0.95) / 3HAC087546-
001 (for CRB 15000-10/1.52 and
CRB 15000-12/1.27)
Lifting aid: 3HAC077789-001
Screws: M3x12 (4 pcs)
xx2000001957
Guide pin, M3x110: 3HAC077787-
001
Always use guide pins in pairs.
For joint units on axes 4, 5 and 6.
xx2000002438
xx2100000041