3
4
5
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Place the two semicircular blocks surrounding the
joint unit, and use two fully threaded attachment
screws as removal tools to press the joint unit out
of position.
Remove the joint unit from the swing.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Remove the lifting aid.
© Copyright 2021 - 2023 ABB. All rights reserved.
5.3.2 Replacing the axis-1 cabling
Note
xx2300000789
xx2300000790
xx2300000778
xx2300000776
Continues on next page
5 Repair
Continued
247