ABB CRB 15000 Product Manual page 482

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.3.7 Replacing the axis-6 cabling
Continued
2
3
Continues on next page
482
Action
Place the arm-side interface at mounting position
and reconnect the connectors.
ASI.DC+
ASI.DC-
ASI.X1
The correct orientation of the arm-side interface
is with the convex button in upper position.
Note
Do not leave the arm-side interface in location
without being secured with the attachment screws.
Refit the arm-side interface with four screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2100000335
xx2100000336
Valid for CRB 15000-5/0.95
Hex socket head cap screw: M3x30
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque: 0.45 Nm
Valid for CRB 15000-10/1.52 and
CRB 15000-12/1.27
Hex socket head cap screw: M3x20
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque: 0.45 Nm
xx2000002550
Product manual - CRB 15000
3HAC077389-001 Revision: L

Advertisement

Table of Contents
loading