5 Repair
5.3.4 Replacing the axis-3 cabling
Continued
3
4
5
6
Continues on next page
354
Action
Fit two guide pins to the axis-3 joint unit.
Remove the remaining attachment screws.
Use two screws as press out screws in the upcom-
ing step, then dispose all screws.
New screws are included in the spare part delivery
of the joint unit.
Put the cabling at the slot in order not to squeeze
it during removal of joint unit.
Press the joint unit out of position using two of
the previous attachment screws as removal tools.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Guide pin, M4x120: 3HAC077786-
001
Always use guide pins in pairs.
For joint units on axes 1, 2 and 3
of CRB 15000-5/0.95 and axis 3 of
CRB 15000-10/1.52 and CRB
15000-12/1.27.
xx2000002576