6
7
Disconnecting the axis-4 joint unit cabling
1
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Disconnect the connectors that belongs to the
axis-5 cabling, from the axis-4 drive board:
D3/4.X2
D3/4.DC-
D3/4.DC+
Use tweezers, if needed.
Pull out the cabling carefully from the tubular.
Action
Disconnect the connectors from the drive board.
CAUTION
Use tweezers to unlock connectors and pull them
off.
D4/5.X1
D4/5.X4
D4/5.X5
© Copyright 2021 - 2023 ABB. All rights reserved.
5.6.6 Replacing the axis-4 joint unit
Note
Tweezers
xx2000002125
Valid for CRB 15000-5/0.95
xx2000002126
Valid for CRB 15000-10/1.52 and
CRB 15000-12/1.27
xx2300000844
Note
Tweezers
xx2000002088
Continues on next page