ABB CRB 15000 Product Manual page 350

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.3.4 Replacing the axis-3 cabling
Continued
6
7
Removing the housing cover (-5/0.95)
1
2
3
Continues on next page
350
Action
Press the upper arm out of position by using two
fully threaded attachment screws as removal
tools.
Remove the upper arm from the lower arm.
Assist the cabling to be removed from the lower
arm while lifting away the complete upper arm.
Place the upper arm on a workbench.
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
Remove the cover screws.
CAUTION
Valid for CRB 15000-5/0.95
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2100000001
xx2000001970
Note
xx2000002021
Product manual - CRB 15000
3HAC077389-001 Revision: L