ABB CRB 15000 Product Manual page 284

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
9
10
11
12
Securing the base (-10/1.52 and -12/1.27)
1
Continues on next page
284
Action
Secure with four attachment screws and pre-
tighten the screws crosswise.
Remove the lifting aid by removing the screws.
Secure the joint unit with the remaining attach-
ment screws.
Torque tighten all screws crosswise.
Action
Lift the base to standing and secure it to the
foundation with the attachment screws and
washers.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2300000796
xx2300000797
Hex socket head cap screw:
3HAB3409-20
xx2300000798
M5x55 12.9 Lafre 2C2B/FC6.9, 12
pcs
Tightening torque: 8.2 Nm.
Note
Attachment screws: M10x35 8.8 (4
pcs).
Washers: 23/10.5/2.5 mm Steel (4 pcs).
Tightening torque: 32 Nm ±10%.
xxx
Product manual - CRB 15000
3HAC077389-001 Revision: L