ABB CRB 15000 Product Manual page 582

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.4.3 Replacing the tubular
Continued
8
9
10
Connecting the axis-4 joint unit cabling
1
Refitting the tilt
1
Continues on next page
582
Action
Torque tighten all screws crosswise.
Remove the lifting aid by removing the screws.
Clean pushed-out flange sealant, if any.
Action
Reconnect the connectors to the drive board.
D4/5.X1 to X1
D4/5.X4 to X4
D4/5.X5 to X5
Action
Fit two guide pins to the axis-5 joint.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Tightening torque: 1.4 Nm (for CRB
15000-5/0.95) / 1.9 Nm (for CRB
15000-10/1.52 and CRB 15000-
12/1.27)
xx2000002090
Note
xx2000002088
Note
Guide pin, M3x110: 3HAC077787-
001
Always use guide pins in pairs.
xx2000002146
Product manual - CRB 15000
3HAC077389-001 Revision: L