ABB CRB 15000 Product Manual page 646

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.4.6 Replacing the arm-side interface
Continued
3
Concluding procedure
1
646
Action
Refit the arm-side interface with four screws.
Action
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Valid for CRB 15000-5/0.95
Hex socket head cap screw: M3x30
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque: 0.45 Nm
Valid for CRB 15000-10/1.52 and
CRB 15000-12/1.27
Hex socket head cap screw: M3x20
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque: 0.45 Nm
xx2000002550
Note
Test run after
90.
Product manual - CRB 15000