3
4
Concluding procedure
1
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Secure the brake release cable with a cable tie.
Refit the cover with the four screws.
Action
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page
© Copyright 2021 - 2023 ABB. All rights reserved.
5.3.9 Replacing the brake release unit
Note
Cable ties
xx2000001931
Hex socket head cap screw: M3x30
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque:
Axis 2: 0.45 Nm
Axis 3: 0.45 Nm
Axis 4: 0.2 Nm
Axis 5: 0.2 Nm
xx2000001935
Note
Test run after
90.