5 Repair
5.6.1 Replacing the axis-1 joint unit (CRB 15000-5/0.95)
Continued
Connecting the axis-2 joint unit cabling
1
2
3
4
Continues on next page
802
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling
the unit read the safety information in section
The unit is sensitive to ESD on page
Reconnect the connectors to the drive board.
D2.X1 to X1
D2.DC+ to DC+
D2.DC- to Ground
D2.X4 to X4
D2.X2 to X2
D2.X5 to X5
Connect the connectors to each other and snap
them to the cable holders.
J2.DC+ to J2.DC+
J2.DC- to J2.DC-
J2.CS to J2.CS
J2.CP to J2.CP
Secure the cables for functional earth and
protective earth with a screw.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
53.
xx2000002013
xx2000001944
Hex socket head cap screw: M3x6 (1
pcs).
Tightening torque: 0.8 Nm.
xx2000001945
Product manual - CRB 15000