5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
Securing the base
1
Refitting the swing(-5/0.95)
1
2
Continues on next page
260
Action
Lift the base to standing and secure it to the
foundation with the attachment screws and
washers.
Action
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the base
mounting surface, as pointed out in the figure.
Separate the new swing parts by removing the
pre-assembling screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Attachment screws: M10x35 8.8 (4
pcs).
Washers: 23/10.5/2.5 mm Steel (4
pcs).
Tightening torque: 32 Nm ±10%.
xx2000002006
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001990