5 Repair
5.4.5 Replacing the tool flange and axis-6 inner flange
Continued
Removing the tool flange
1
2
3
4
Continues on next page
638
Action
Remove the tool flange screws and washers.
CAUTION
Valid for CRB 15000-5/0.95
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
Cut the cable ties.
Disconnect the CP/CS connectors from the drive
board and remove the tool flange.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2000002155
xx2000002157
xx2000002158
Product manual - CRB 15000
3HAC077389-001 Revision: L