5 Repair
5.6.6 Replacing the axis-4 joint unit
Continued
Connecting the tilt cabling
1
2
3
Continues on next page
966
Action
Insert the cabling into the tubular.
Reconnect the connectors to the drive board.
D3/4.X2 to X2
D3/4.DC- to Ground
D3/4.DC+ to +DC
Connect the connectors to each other and snap
them to the cable holders.
J4/5.DC+ to J5/6.DC+
J4/5.DC- to J5/6.DC-
J4/5.CS to J5/6.CS
J4/5.CP to J5/6.CP
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Valid for CRB 15000-5/0.95
xx2000002148
Valid for CRB 15000-10/1.52 and
CRB 15000-12/1.27
xx2300000845
xx2000002125
xx2000002089
Product manual - CRB 15000