3
Refitting the upper arm
1
2
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Refit the cover with the four screws.
Action
Fit two guide pins to the axis-3 joint.
Valid for CRB 15000-5/0.95
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the lower
arm mounting surface, as pointed out in the figure.
© Copyright 2021 - 2023 ABB. All rights reserved.
5.6.5 Replacing the axis-3 joint unit
Note
Hex socket head cap screw: M3x30
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque: 1.4 Nm
xx2300000833
Note
Guide pin, M4x120: 3HAC077786-
001
xx2000001971
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001973