4
5
6
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Secure the cable plate to the joint unit with the
attachment screws.
Connect the two connectors to the torque sensor
board.
TQ.A to CH1/A
TQ.B to CH2/B
Insert the cabling through the cable support and
fit the support to the drive board with the attach-
ment screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
5.3.6 Replacing the axis-5 cabling
Note
Hex socket head cap screw:
M2.5x6 12.9 Lafre 2C2B/FC6.9 (4
pcs)
Tightening torque: 0.45 Nm.
xx2000002049
xx2000002053
xx2000002056
Hex socket head cap screw: M3x30
12.9 Lafre 2C2B/FC6.9 (2 pcs)
Tightening torque: 0.45 Nm.
xx2000002055
Continues on next page
5 Repair
Continued