Disconnecting the axis-6 joint unit cabling
1
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
CAUTION
There is cabling connected between the arm-side
interface and the joint unit drive board.
Open the arm-side interface with care to avoid
damage to the cabling or the connector(s).
Do not leave the arm-side interface in location
without being secured with the attachment screws.
Remove the attachment screws.
Loosen the arm-side interface carefully and dis-
connect the connectors from it.
ASI.DC+
ASI.DC-
ASI.X1
Action
Cut the cable ties.