ABB CRB 15000 Product Manual page 140

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

3 Installation and commissioning
3.6.5 Configuration of SafeMove using Visual SafeMove in RobotStudio
Continued
Uploading the settings to the controller
140
7 In the Visual SafeMove browser, right-click Tool Speed Supervisions and
choose Create Global Tool Speed Supervision.
Parameter
Activation
Function active status
Violation action
Settings
8 In the Visual SafeMove browser, right-click Stand Still Supervisions and
choose Create Global Stand Still Supervision.
Parameter
Activation
Function active status
Violation action
Tolerances
1 In the Visual SafeMove ribbon tab, click Controller in the Configuration
group.
2 Click Write to controller.
The configurations are uploaded to the controller after the controller restarts.
© Copyright 2021 - 2023 ABB. All rights reserved.
Value
ISH_Supervise_TSP
ISH_TSP_Active
Stop category
Category1Stop
Signal
ISH_TSP_Viol
Max speed (mm/s)
250.000
Min speed (mm/s)
Leave blank
Value
ISH_Supervise_SST
ISH_SST_Active
Stop category
Category0Stop
Signal
ISH_SST_Viol
Enabled for all joints and remain
default tolerance values.
Product manual - CRB 15000
3HAC077389-001 Revision: L

Advertisement