5
6
7
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Secure the tubular to the housing with all attach-
ment screws but two.
Pre-tighten the screws crosswise firstly.
Remove the guide pins and fasten the remaining
two screws.
Torque tighten all screws crosswise.
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing
Continued
Note
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111
xx2000002081
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111
xx2000002079
Tightening torque: 1.8 Nm.
Continues on next page
543