Disconnecting the axis-3 joint unit cabling
1
2
3
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Cut the cable ties.
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J4.DC+
J4.DC-
J4.CS
J4.CP
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing
Continued
Note
xx2000002066
xx2000001945
xx2000002067
Continues on next page