5 Repair
5.3.2 Replacing the axis-1 cabling
Continued
Securing the base (-10/1.52 and -12/1.27)
1
Removing the swing (-10/1.52 and -12/1.27)
1
2
Continues on next page
248
Action
Lift the base to standing and secure it to the
foundation with the attachment screws and
washers.
Action
Valid for CRB 15000-10/1.52
Remove the swing transition.
Valid for CRB 15000-10/1.52
Remove the swing flange.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Attachment screws: M10x35 8.8 (4
pcs).
Washers: 23/10.5/2.5 mm Steel (4 pcs).
Tightening torque: 32 Nm ±10%.
xxx
Note
xx2300000817
xx2300000818