Removing the joint cabling (-10/1.52 and -12/1.27)
Use these procedures to remove the joint-2 cabling.
Preparations before removing the cabling
1
2
Removing the lower arm covers (-10/1.52 and -12/1.27)
1
2
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Jog the robot to the specified position: xxx
•
Axis 1: 0°
•
Axis 2: 0° (home position)
•
Axis 3: +60°
•
Axis 4: 0°
•
Axis 5: -90°
•
Axis 6: No significance.
CAUTION
Jog the axis on which the joint unit is to be re-
placed to home position, to achieve correct cable
routing during replacement of the joint unit.
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
Remove the lower cover of lower arm by removing
the screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
5.3.3 Replacing the axis-2 cabling
Note
xx2100000044
Note
xx2300000812
Continues on next page
5 Repair
Continued
305