dial-backup connect-timeout <value>
Use the dial-backup connect-timeout command to specify the number of seconds to wait for a connection
after a call is attempted before trying to call again or dialing a different number. It is recommended this
number be greater than 60. Use the no form of this command to return to the default setting. For more
detailed information on dial-backup functionality, refer to the Functional Notes and Technology Review
sections of
dial-backup call-mode on page
Syntax Description
<value>
Default Values
By default, the dial-backup connect-timeout period is set to 60 seconds.
Command History
Release 1.1
Usage Examples
The following example configures AOS to wait 120 seconds before retrying a failed dial-backup call:
(config)#interface frame-relay 1.16
(config-fr 1.16)#dial-backup connect-timeout 120
60000CRG0-35E
2203.
Selects the amount of time (in seconds) that the router will wait for a
connection before attempting another call. Valid range is 10 to 300 seconds.
Command was introduced.