Mdeu Key Registers - Freescale Semiconductor MPC8313E Family Reference Manual

Powerquicc ii pro integrated processor
Hide thumbs Also See for MPC8313E:
Table of Contents

Advertisement

initialized, regardless of mode selected, however only the appropriate context register values are used in
hash generation per the mode selected. The user typically does not care about the MDEU context register
initialization values, however they are documented for completeness in the event the user reads these
registers using host-controlled access. MDEU reset through the MDEU reset control register
(MDEURCR)
(Figure
Name
MD-5
SHA-1
SHA-224
SHA-256
Name
MD-5
SHA-1
SHA-256
Name
MD-5
SHA-1
SHA-256
Name
MD-5
SHA-1
SHA-256
Name
Reset

14.4.2.12 MDEU Key Registers

The MDEU maintains eight 64-bit registers for writing an HMAC key. The IPAD and OPAD operations
are performed automatically on the key data when required.
MPC8313E PowerQUICC II Pro Integrated Processor Family Reference Manual, Rev. 3
Freescale Semiconductor
14-19) or SEC global software reset
0
A
0x01234567
0x67452301
0xC1059ED8
0x6A09E667
C
0xFEDCBA98
0x98BADCFE
0x3070DD17
0x3C6EF372
E
0xF0E1D2C3
0xC3D2E1F0
0xFFC00B31
0x510E527F
G
0xABD9831F
0x1F83D9AB
0x64F98FA7
0x1F83D9AB
Message Length Count
Figure 14-25. MDEU Context Registers
(Figure
14-47) does not clear these registers.
31
32
B
0x89ABCDEF
0xEFCDAB89
0x367CD507
0xBB67AE85
D
0x76543210
0x10325476
0xF70E5939
0xA54FF53A
F
0x8C68059B
0x9B05688C
0x68581511
0x9B05688C
H
0x19CDE05B
0x5BE0CD19
0xBEFA4FA4
0x5BE0CD19
0
Security Engine (SEC) 2.2
63
Context
offset
0x3_6100
Context
offset
0x3_6108
Context
offset
0x3_6110
Context
offset
0x3_6118
Context
offset
0x3_6120
14-39