switchport mode trunk

Use this command to set the switching characteristics of the port to trunk. Received frames are
classified based on the VLAN characteristics, then accepted or discarded based on the specified
filtering criteria.
Syntax
switchport mode trunk [ingress-filter {enable|disable}]
Parameter
ingress-filter
enable
disable
By default, ports are in access mode, are untagged members of the default VLAN (vlan1), and
Default
have ingress filtering on.
Interface mode
Mode
A port in trunk mode can be a tagged member of multiple VLANs, and an untagged member
Usage
of one native VLAN.
To configure which VLANs this port will trunk for, use the
command.
Examples
awplus(config-if)#
C613-50007-01 REV B
Description
Set the ingress filtering for the frames received.
Turn on ingress filtering for received frames. This is the default
value.
Turn off ingress filtering to accept frames that do not meet the
classification criteria.
awplus#
configure terminal
awplus(config)#
interface port1.1.3
switchport mode trunk ingress-filter enable