RIPng Configuration

Troubleshooting RIPng Adjacency

Follow the steps below to troubleshoot RIPng adjacency:

Step 1. Confirm the Interface is not shutdown

awplus#configure terminal
awplus(config)#interface vlan2
awplus(config-if)#no shutdown
awplus(config-if)#exit
awplus(config)#exit
awplus#show ipv6 interface brief

Step 2. Confirm RIPng is enabled on the Interface

awplus#configure terminal
awplus(config)#interface vlan2
awplus(config-if)#ipv6 router rip
awplus(config-if)#exit
awplus(config)#exit
awplus#show ipv6 rip interface vlan2
vlan2 is up, line protocol is up
Routing Protocol: RIPng
Passive interface: Disabled
Split horizon: Enabled with Poisoned
Reversed
IPv6 interface address:
3ffe:1::10/64
fe80::204:76ff:fec8:28cc/10
33.4
Software Reference for SwitchBlade® x908, x900 and x600 Series Switches
TM
AlliedWare Plus
Operating System - Software Version 5.3.1
Enter the Configure mode.
Specify the interface (vlan2) and enter the
Interface mode.
Ensure the interface is not administratively shutdown.
Exit Interface mode and enter Configure
mode.
Exit Configure mode and return to Privileged
Exec mode.
User the show interface command to make sure
that the interface is not administratively shutdown.
Enter the Configure mode.
Specify the interface (vlan2) and enter the
Interface mode.
Enable RIPng routing is enabled on interface
port1.0.1.
Exit Interface mode and enter Configure
mode.
Exit Configure mode and return to Privileged
Exec mode.
Enable RIPng routing on interface vlan2.