Log Permanent - Allied Telesis SwitchBlade x908 Series Software Reference Manual

Switchblade x908/x900 series alliedware plus operating system software reference for version 5.3.1
Hide thumbs Also See for SwitchBlade x908 Series:
Table of Contents

Advertisement

To remove a filter that sends all messages generated by BGP that have a severity of "notices" or
higher to the terminal use the command:
awplus(config)#
To remove a default filter that include everything sending to the terminal use the command:
awplus(config)#
show log config
Validation
Commands
terminal monitor
Related Commands

log permanent

Configures the device to send log messages to non-volatile storage (NVS) on the device. Log
messages sent to NVS are retained on the device over a restart, that is they are permanent.
Once the permanent log reaches its configured maximum allowable size old messages will be
deleted to make way for new ones.
The no form of the command configures the device not to send any messages to the
permanent log. Log messages will not be retained over a restart.
Syntax
log permanent
no log permanent
Parameter
log
permanent
no
Global Configuration mode
Mode
To enable permanent logging use the command:
Examples
awplus(config)#
To disable permanent logging use the command:
awplus(config)#
show log config
Validation
Commands
default log permanent
Related Commands
log permanent (filter)
log permanent size
show log permanent
C613-50007-01 REV B
no log monitor level notices program bgp
no log monitor level debugging
Description
Logging control
Send messages to the permanent log.
Stop sending messages to the permanent log.
log permanent
no log permanent
Software Reference for SwitchBlade® x908, x900 and x600 Series Switches
TM
AlliedWare Plus
Operating System - Software Version 5.3.1
Logging Commands
10.29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents