OSPF Commands

overflow database

Use this command to limit the maximum number of Link State Advertisements (LSAs) that can
be supported by the current OSPF instance.
Use the no parameter with this command to have no limit on the maximum number of LSAs.
Syntax
overflow database <0-4294967294> {hard|soft}
no overflow database
Parameter
<0-4294967294>
hard
soft
Router mode
Mode
Use hard with this command if a shutdown is required if the number of LSAs exceeds the
Usage
specified number. Use soft with this command if a shutdown is not required, but a warning
message is required, if the number of LSAs exceeds the specified number.
The following example shows setting the database overflow to 500, and a shutdown to occur,
Examples
if the number of LSAs exceeds 500.
awplus(config-router)#
36.50
Description
The maximum number of LSAs
Shutdown occurs if the number of LSAs exceeds the specified value.
Warning message appears if the number of LSAs exceeds the specified
value.
awplus#
configure terminal
awplus(config)#
router ospf 100
overflow database 500 hard