Clock Set - Allied Telesis SwitchBlade x908 Series Software Reference Manual

Switchblade x908/x900 series alliedware plus operating system software reference for version 5.3.1
Hide thumbs Also See for SwitchBlade x908 Series:
Table of Contents

Advertisement

System Configuration and Monitoring Commands

clock set

This command sets the time and date for the system clock.
Syntax
clock set <hh:mm:ss> <day> <month> <year>
Parameter
<hh:mm:ss>
<day>
<month>
<year>
Privileged Exec mode.
Mode
Configure the timezone before setting the local time. Otherwise, when you change the
Usage
timezone, the device applies the new offset to the local time.
Note:
To set the time and date on your system to 2pm on the 2nd of April 2007, use the command:
Example
clock timezone
Related Commands
show clock
8.6
Description
Local time in 24-hour format
Day of the current month
The first three letters of the current month.
Current year
If Network Time Protocol (NTP) is enabled, then you cannot change the time or date
using this command. NTP maintains the clock automatically using an external time
source. If you wish to manually alter the time or date, you must first disable NTP.
awplus#
clock set 14:00:00 2 apr 2007
Software Reference for SwitchBlade® x908, x900 and x600 Series Switches
TM
AlliedWare Plus
Operating System - Software Version 5.3.1
<1-31>
<2000-2035>
C613-50007-01 REV B

Hide quick links:

Advertisement

Table of Contents
loading