OSPF Commands

timers spf

Use this command to adjust route-calculation timers.
Use the no parameter with this command to return to the default timer values.
Syntax
timers spf <spf_delay> <spf_holdtime>
no timers spf
Parameter
<spf_delay>
<spf_holdtime>
Router mode
Mode
This command configures the delay time between the receipt of a topology change and the
Usage
calculation of the Shortest Path First (SPF). This command also configures the hold time
between two consecutive SPF calculations.
Examples
awplus(config-router)#
36.80
Description
<0-2147483647> Specifies the delay between receiving changed
routing information and embarking on an SPF calculation.
The default spf-delay value is 5 seconds
<0-2147483647> Specifies hold time between consecutive SPF
calculations. The default spf-holdtime value is 10 seconds.
awplus#
configure terminal
awplus(config)#
router ospf 100
timers spf 7 12