Ip Irdp Minadvertinterval - Allied Telesis SwitchBlade x908 Series Software Reference Manual

Switchblade x908/x900 series alliedware plus operating system software reference for version 5.3.1
Hide thumbs Also See for SwitchBlade x908 Series:
Table of Contents

Advertisement

ip irdp minadvertinterval

This command sets the minimum time allowed between sending router advertisements from
the interface. If you change the minadvertisementinterval value, also change the lifetime
and the maxadvertisementinterval to maintain the following ratios:
lifetime=3 x maxadvertisementinterval
minadvertisementinterval=0.75 x maxadvertisementinterval
You cannot set the minimum advertisement interval above the maximum interval. If you are
raising the minimum interval to a value above the current maximum interval, you must change
the maximum value first.
The no form sets the minadvertinterval back to the default of 450 seconds.
Syntax
ip irdp minadvertinterval <3-1800>
no ip irdp minadvertinterval
Parameter
<3-1800>
Interface mode
Mode
The IRDP minimum advertisement interval is set to 450 seconds (7.5 minutes) by default.
Default
To set the minimum interval between advertisements on vlan4 to 900 seconds, use the
Examples
command:
awplus(config-if)#
To set the minimum interval between advertisements on vlan4 back to the default of 450
seconds, use the command:
awplus(config-if)#
ip irdp
Related Commands
ip irdp lifetime
ip irdp maxadvertinterval
show ip irdp interface
C613-50007-01 REV B
Description
The minimum time between advertisements in seconds.
Default: 450
awplus#
configure terminal
awplus(config)#
interface vlan4
ip irdp minadvertinterval 900
awplus#
configure terminal
awplus(config)#
interface vlan4
no ip irdp minadvertinterval