Log Console (Filter) - Allied Telesis SwitchBlade x908 Series Software Reference Manual

Switchblade x908/x900 series alliedware plus operating system software reference for version 5.3.1
Hide thumbs Also See for SwitchBlade x908 Series:
Table of Contents

Advertisement

log console (filter)

Creates a filter to select messages to be sent to all consoles when the log console command is
given. Selection can be based on the priority/severity of the message, the program that
generated the message, the logging facility used, a sub-string within the message or a
combination of some or all of these. By default the buffered log has a filter to select messages
whose severity level is "critical" or higher. This filter may be removed using the "no" form of this
command. This filter may be removed and replaced by filters that are more selective.
Syntax
log console
no log console
Parameter
log
console
no
level
<level>
C613-50007-01 REV B
[level <level>]
[program <program-name>]
[facility <facility>]
[msgtext <text-string>]
[level <level>]
[program <program-name>]
[facility <facility>]
[msgtext <text-string>]
Description
Logging control
Set console logging parameters
Deletes the specified filter, so that corresponding messages are no longer
sent to the console.
Filter messages by severity level.
The minimum severity of message to send. The level can be specified as
one of the following numbers or level names, where 0 is the highest
severity and 7 is the lowest severity:
0 emergencies:
1|alerts
2|critical
3|errors
4|warnings
5|notices
6|informational
7|debugging
Software Reference for SwitchBlade® x908, x900 and x600 Series Switches
TM
AlliedWare Plus
Operating System - Software Version 5.3.1
System is unusable
Action must be taken immediately
Critical conditions
Error conditions
Warning conditions
Normal, but significant, conditions
Informational messages
Debug-level messages
Logging Commands
10.15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents