Allied Telesis AT-8948 Installation And Safety Manual
Allied Telesis AT-8948 Installation And Safety Manual

Allied Telesis AT-8948 Installation And Safety Manual

X900 series switch and switchblade x908
Hide thumbs Also See for AT-8948:

Advertisement

x900 Series Switch and SwitchBlade
x908
®
Installation and Safety Guide
AT-8948
x900-48FE
x900-48FE-N
x900-48FS
AT-9924T
AT-9924SP
AT-9924Ts
x900-12XT/S
x900-24XT
x900-24XT-N
x900-24XS
SwitchBlade
x908
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AT-8948 and is the answer not in the manual?

Questions and answers

Summary of Contents for Allied Telesis AT-8948

  • Page 1 Series Switch and SwitchBlade x908 ® Installation and Safety Guide AT-8948 x900-48FE x900-48FE-N x900-48FS AT-9924T AT-9924SP AT-9924Ts x900-12XT/S x900-24XT x900-24XT-N x900-24XS SwitchBlade x908 ®...
  • Page 2 ® x900 Series Switch and SwitchBlade x908 Installation and Safety Guide AT-8948 AT-9924Ts x900-48FE x900-12XT/S x900-48FE-N x900-24XT x900-48FS x900-24XT-N AT-9924T x900-24XS ® AT-9924SP SwitchBlade x908 Download the complete document set from www.alliedtelesis.com/support/software...
  • Page 3 Installation and Safety Guide Document Number C613-04052-00 REV P © 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis, Inc. reserves the right to change specifications and other information in this document without prior written notice.
  • Page 4: Table Of Contents

    Installation and Safety Guide Contents About this Guide ......................4 Package Contents ......................4 Selecting a Site ........................6 Installing the Switch ......................7 Applying Power to the Switch ..................11 Connecting to the Switch ..................... 17 Checking LEDs ........................ 25 Obtaining Documentation and Resources ...............
  • Page 5: About This Guide

    Package Contents Depending on the model, the switch is factory-fitted with the following power supply and fan options: ■ AT-8948, AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches have a PSU and a FOM installed. ■ AT-9924T, AT-9924SP, x900-48FE, x900-48FE-N, and x900-48FS switches have a PSU and a blanking plate installed.
  • Page 6 Installation and Safety Guide The following items are shipped with each switch. Contact your authorised distributor or reseller if any are damaged or missing. All models ship with: ■ one cable for connecting the switch to a terminal or PC ■...
  • Page 7: Selecting A Site

    Before you install the switch, review the following considerations about its location. ■ AT-8948, x900-48FE, x900-48FS, and AT-9900 switches require an ambient temperature from 0º C to 50ºC (32º F to 122º F). ■ AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches require an ambient temperature from 0º...
  • Page 8: Installing The Switch

    Installation and Safety Guide Installing the Switch Ports on the switch are suitable only for connections within buildings (intra- building) and with cables unexposed to the outside. You can install the switch on a level surface, such as a desktop or bench, or in a standard 19-inch rack.
  • Page 9 ® x900 Series Switch and SwitchBlade x908 ■ All bare conductors must be coated with an appropriate antioxidant compound before making crimp connections. Warning Both AC and DC versions of this equipment must be earthed through the power cables provided. On a level surface Ensure the area has sufficient space for the switch and its cables.
  • Page 10 Installation and Safety Guide In a 19-inch rack Ensure the rack has sufficient space for the switch and its cables. For the switch’s requirements, see “Selecting a Site” on page Install cage nuts at the front of the rack so they are ready for the rack- mount screws in the following steps.
  • Page 11 ® x900 Series Switch and SwitchBlade x908 Fitting a bracket on a SwitchBlade x908 switch Fitting a bracket on all other x900 Series switches Mount the switch into the rack from the front, and tighten the rack-mount screws. Two people are required at this point. One person can lift the switch into the rack and attach it to the front rails while the second person safely supports it from the rear.
  • Page 12: Applying Power To The Switch

    Installation and Safety Guide Applying Power to the Switch Power supply bays are in the rear of the switch. Depending on the model, the switch may have a PSU, FOM, or blanking plate over a power supply bay. Connecting an AC power supply Follow these instructions to connect one of the following to an AC power supply: ■...
  • Page 13 ® x900 Series Switch and SwitchBlade x908 Plug the AC power cord that is provided into the power inlet on the PSU. Connect the power cord to the main power source. On the AT-PWR05, set the Run/Standby switch to Run. Check that the PSU LED on the front panel of the switch is lit green.
  • Page 14 Installation and Safety Guide Warning When SBx908 devices are connected with VCS stacking cables (either HS-STK-CBL or XEM-STK-CBL), each individual stack member chassis must be additionally grounded by using the rear grounding-terminal on each device. In order to avoid large circulating ground currents, the wires of each grounding cable must be 18AWG or thicker.
  • Page 15 ® x900 Series Switch and SwitchBlade x908 Ensure that the circuit breaker is off for the supply circuit and the Run/ Standby switch on the PSU. Release the Run/Standby switch so that it is not pushed in (which is the Off position). Connect the supply cable wires to the circuit breaker.
  • Page 16 Installation and Safety Guide PWR05 PWR05 DC Power supply specifications: ■ functional range 40 to 60 V, 48 V nominal ■ supports either positive grounded or negative grounded operation ■ a 30 Amp certified/listed circuit breaker is required for circuit protection Supply cable specifications: ■...
  • Page 17 ® x900 Series Switch and SwitchBlade x908 Confirm that the switch is receiving power. Check that the PSU LED on the front panel of the switch corresponding to the PSU bay lights green. If the LED does not light green, check the Run/ Standby switch.
  • Page 18: Connecting To The Switch

    Installation and Safety Guide Connecting to the Switch All x900 Series switches and the SwitchBlade x908 can be configured using the Command Line Interface (CLI) and the Graphical User Interface (GUI). The procedure and command syntax varies depending on whether the switch is ®...
  • Page 19 ® x900 Series Switch and SwitchBlade x908 When x900-24XT, x900-24XT-N, x900-24XS, or SwitchBlade x908 switches are connected to form a virtual chassis stack (VCS), the ETH0 port has additional operational functions. See the Hardware Reference for more information. From the terminal or PC, Telnet to the IP address of the ETH0 port. To use the ASYN0/CONSOLE port, physically connect it to the terminal or PC with the RJ-45 DB9 cable that is supplied.
  • Page 20 Installation and Safety Guide Configure the switch. Refer to the AlliedWare Plus™ Operating System Software Reference for detailed information about configuring the software. For online help, type ? after: • the prompt, to list all commands available in the command mode you are in •...
  • Page 21 ® x900 Series Switch and SwitchBlade x908 Using the AlliedWare Plus Operating System GUI Follow this procedure to establish a connection to an x900 or x908 series switch, so you can use the GUI to configure the switch. Select a PC to use and identify its subnet. You can browse to the switch from any PC running a supported operating system with a supported browser with JavaScript enabled.
  • Page 22 Installation and Safety Guide Save the configuration. Save the current configuration as the default startup configuration by using the commands: awplus>enable awplus#copy running-config startup-config Alternatively, you can save the current configuration with a different file name and then set the switch to load this file when it restarts by using the commands: awplus>enable awplus#copy running-config <filename>.cfg...
  • Page 23 ® x900 Series Switch and SwitchBlade x908 Using the AlliedWare Operating System CLI Depending on the model, an ASYN0/CONSOLE and/or ETH0 port is on the front of the switch for installation and maintenance. To use the ETH0 port, physically connect it to the terminal or PC, and check that the port’s LEDs are lit.
  • Page 24 To change the account password, use the set password command. Configure online help. To use online help you must first configure the help file by using one of these commands: For AT-8948, x900-48FE, x900-48FE-N, x900-48FS, and AT-9900 switches, use: set help=<filename>.hlp For AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches, use: set install=preferred help=help-filename Help files have an HLP extension.
  • Page 25 ® x900 Series Switch and SwitchBlade x908 Using the AlliedWare Operating System GUI Follow this procedure to establish a connection to an AT-9900 series switch, so you can use the GUI to configure the switch. Select a PC to use and identify its subnet. You can browse to the switch from any PC running a supported operating system with a supported browser.
  • Page 26: Checking Leds

    A FOM is installed in the switch and a fan has failed. The x900-12XT/S and SwitchBlade x908 switches do not support FOMs. • The bay is empty. Applies to AT-8948, AT-9924Ts, x900-24XT, x900-24XT-N, and x900-24XS switches which require a FOM when only one PSU is installed.
  • Page 27 SwitchBlade x908 switches. Green The CompactFlash memory card is active and should flashing not be ejected. The card can be safely ejected when the LED remains off. Valid for AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9924T, and AT-9924SP switches.
  • Page 28 Installation and Safety Guide State Description (cont) Green The Secure Digital memory card is active and should flashing not be ejected. The card can be safely ejected when the LED remains off. Valid for AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches. Stacking The following table describes how LEDs on the SwitchBlade x908 report operations and faults on the rear panel stacking ports.
  • Page 29 ® x900 Series Switch and SwitchBlade x908 PWR05 The following is a diagram of the LEDs in the PWR05 power supply units: LEDs FAULT POWER CONNECTOR PWR05 The following table describes LEDs on the PWR05 AC power supply unit for the SwitchBlade x908.
  • Page 30 Installation and Safety Guide PWR05 The following table describes LEDs on the PWR05 DC power supply unit for the SwitchBlade x908. LEDs State Description Green DC input voltage is within 40 VDC to 60 VDC. DC input voltage is outside the acceptable range. Green DC output voltage is within 12VDC +/- 10%.
  • Page 31: Obtaining Documentation And Resources

    You can download it from www.adobe.com. Other resources How-To Notes describe a range of standard Allied Telesis solutions, and include technical tips and guides to configuring specific hardware and software features. You can download the latest How-To Notes from www.alliedtelesis.com/resources/literature/howto.aspx.
  • Page 32 Contacting us With locations covering all of the established markets in North America, Latin America, Europe, Asia, and the Pacific, Allied Telesis provides localized sales and technical support worldwide. To find the representative nearest you, visit us on the Web at www.alliedtelesis.com.
  • Page 33: Standards

    ® x900 Series Switch and SwitchBlade x908 Standards Where applicable, the products in this document meet the following standards: Category Approval Agency and Requirement Safety UL60950-1 EN 60825-1 CAN/CSA-C22.2 No. 60950-1-03 EN 60825-2 EN60950-1 21 CFR 1040 AS/NZS 60950.1 Electromagnetic FCC CFR47 Part 15 Class A CNS 13438 Class A EN55022 Class A...
  • Page 34: Safety

    CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling. OPERATING TEMPERATURE: The AT-8948, x900-48FE, x900-48FE-N, x900-48FS, and AT-9900 series switches are designed for a maximum ambient temperature of 50 degrees C. The AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and SwitchBlade x908 switches are designed for a maximum of 40 degrees C.
  • Page 35 ® x900 Series Switch and SwitchBlade x908 Lithium Battery - Should be changed only by authorised service personnel. CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with Lithium Battery, type CR2032, and dispose of in accordance with the manufacturer’s recommendations and all local codes.
  • Page 36: Sicherheit

    Die Entlüftungsöffnungen dürfen nicht blockiert sein und müssen zum Kühlen freien Zugang zur Raumluft haben. BETRIEBSTEMPERATUR: AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 50 grad C entworfen. Die AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 produkt wurde für...
  • Page 37 ® x900 Series Switch and SwitchBlade x908 Lithium-Batterie - Sollte nur von einem geschulten qualifizierten Techniker ausgetauscht werden. VORSICHT: Explosionsgefahr bei unsachgemäßem Austausch der Batterie. Nur mit einer gleichen Batterie oder einem gleichwertigen Batterietyp nach Empfehlung des Herstellers ersetzen. Gebrauchte Batterien nach Anweisungen des Herstellers beseitigen.
  • Page 38: Sikkerhed

    ADVARSEL: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den omgivende luft i rummet for afkøling. BETJENINGSTEMPERATUR: AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series apparat er konstrueret til en omgivende temperatur på maksimum 50 grader C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 apparat er konstrueret til en omgivende temperatur på...
  • Page 39 ® x900 Series Switch and SwitchBlade x908 med samme eller en tilsvarende type der anbefales af producenten. Kassér brugte batterier i overensstemmelse med producentens instruktioner. ALLE LANDE: Installation af produktet skal ske i overensstemmelse med lokal og national lovgivning for elektriske installationer. Advarsel: ETABLERES FORBINDELSEN TIL ET JÆVNSTRØMSNET, BØR INSTALLERING FORETAGES I ET OMRÅDE HVOR UVEDKOMMENDE IKKE HAR ADGANG.
  • Page 40: Veiligheid

    OPGELET: De ventilatiegaten mogen niet worden gesperd en moeten de omgevingslucht ongehinderd toelaten voor afkoeling. BEDRIJFSTEMPERATUUR: De omgevingstemperatuur voor AT-8948, x900- 48FE, x900-48FE-N, x900-48FS, AT-9900 series produkt mag niet meer bedragen dan 50 graden C. De omgevingstemperatuur voor AT-9924Ts, x900- 12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 produkt mag niet meer bedragen dan 40 graden C.
  • Page 41 ® x900 Series Switch and SwitchBlade x908 Lithium batterij. Mag alleen worden vervangen door een daartoe opgeleide en bevoegde technicus. OPGELET: Gevaar voor ontploffing indien de batterij verkeerd wordt vergangen. Alleen vervangen door hetzelfde of een gelijkwaardig, door de fabrikant aanbevolen type. ALLE LANDEN: het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften.
  • Page 42: Sécurité

    ATTENTION: Ne pas bloquer les fentes d’aération, ceci empêcherait l’air ambiant de circuler librement pour le refroidissement. TEMPÉRATURE DE FONCTIONNEMENT: AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series est capable de tolérer une température ambiante maximum de ou 50 degrés C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 est capable de tolérer...
  • Page 43 ® x900 Series Switch and SwitchBlade x908 ATTENTION : RÉPARTITION DE LA CHARGE MÉCANIQUE - Le montage du matériel dans le bâti doit être effectué de telle manière que la répartition de la charge mécanique ne pose aucun danger. Pile en Lithium-Doit uniquement être remplacée par un technicien dûment qualifié...
  • Page 44: Turvallisuus

    HUOMAUTUS: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi. KÄYTTÖLÄMPÖTILA: Tämä AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series katkaisin on suunniteltu ympäröivän ilman maksimilämpötilalle 50° C. Tämä AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 tuote on suunniteltu ympäröivän...
  • Page 45 ® x900 Series Switch and SwitchBlade x908 Litiumparisto - Vaihdon voi suorittaa vain koulutettu ja pätevä teknikko. Varoitus: Räjähdysvaara, jos paristo on vaihdettu väärin. Vaihda vain samaan tai vastaavaan tyyppiin, jota valmistaja suosittelee. Hävitä käytetyt paristot valmistajan ohjeiden mukaan. KAIKKI MAAT: Asenna tuote paikallisten ja kansallisten sähköturvallisuusmääräysten mukaisesti.
  • Page 46: Norme Di Sicurezza

    ATTENZIONE: le prese d’aria non vanno ostruite e devono consentire il libero ricircolo dell’aria ambiente per il raffreddamento. TEMPERATURA DI FUNZIONAMENTO: AT-8948, x900-48FE, x900- 48FE-N, x900-48FS, AT-9900 series prodotto è concepito per una temperatura ambientale massima di 50 gradi C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 prodotto è...
  • Page 47 ® x900 Series Switch and SwitchBlade x908 Batteria al litio - Va sostituita solo da un tecnico specializzato e qualificato. ATTENZIONE: l'errata sostituzione della batteria può causare pericolo di esplosioni. Sostituire solamente con lo stesso tipo o con uno equivalente raccomandato dal produttore.
  • Page 48: Sikkerhet

    FORSIKTIG: Lufteventilene må ikke blokkeres, og må ha fri tilgang til luft med romtemperatur for avkjøling. DRIFTSTEMPERATUR: AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series produktet er konstruert for bruk i maksimum romtemperatur på 50 grader C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 produktet er konstruert for bruk i maksimum romtemperatur på...
  • Page 49 ® x900 Series Switch and SwitchBlade x908 ALLE LAND: Produktet må installeres i samsvar med de lokale og nasjonale elektriske koder. Advarsel: VED TILKOPLING TIL ET LIKESTRØMSNETT, SKAL DU BARE MONTERE UTSTYRET PÅ ET STED HVOR UVEDKOMNE IKKE HAR ADGANG. Merknad: En kanalkabel er nødvendig for å...
  • Page 50: Segurança

    CUIDADO: As aberturas de ventilação não devem ser bloqueadas e devem ter acesso livre ao ar ambiente para arrefecimento adequado do aparelho. TEMPERATURA DE FUNCIONAMENTO: AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series produto foi projetado para uma temperatura ambiente máxima de 50 graus C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 produto foi projetado para uma temperatura ambiente máxima de 40 graus C.
  • Page 51 ® x900 Series Switch and SwitchBlade x908 Bateria de lítio - Só deve ser trocada por técnico qualificado e treinado. CUIDADO: Se a bateria não for devidamente instalada há perigo de explosão. Substitua somente pelo mesmo tipo ou equivalente, conforme recomendado pelo fabricante.
  • Page 52: Seguridad

    ATENCION: Las aberturas para ventilación no deberán bloquearse y deberán tener acceso libre al aire ambiental de la sala para su enfriamiento. TEMPERATURA REQUERIDA PARA LA OPERACIÓN: AT-8948/ x900-48/AT-9900 producto está diseñado para una temperatura ambiental máxima de 50 grados C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 producto está...
  • Page 53 ® x900 Series Switch and SwitchBlade x908 ATENCION: CARGA MECANICA - El montaje del equipo en el bastidor debe realizarse de manera tal que no cause una condición peligrosa debido a la distribución desigual del peso. Batería de litio - Sólo deberá ser cambiada por un técnico entrenado y calificado. ATENCION: Peligro de explosión si la batería no se reemplaza en forma correcta.
  • Page 54: Säkerhet

    VARNING: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande rumsluft för avsvalning. DRIFTSTEMPERATUR: AT-8948, x900-48FE, x900-48FE-N, x900-48FS, AT-9900 series produkt är konstruerad för rumstemperatur ej överstigande 50 grader C. AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, SwitchBlade x908 produkt är konstruerad för rumstemperatur ej överstigande 40 grader C.
  • Page 55 ® x900 Series Switch and SwitchBlade x908 Litium batteri - Får endast bytas av utbildade och kvalificerade tekniker. VARNING: Risk för explosion om felaktigt batteri används. Byt endast mot samma eller likvärdig typ batteri, rekommenderat av tillverkaren. Kassera använda batterier i enlighet med tillverkarens instruktioner. ALLA LÄNDER: Installera produkten i enlighet med lokala och statliga bestämmelser för elektrisk utrustning.