To create a filter to send all messages containing the text "Bridging initialization" to console
instances where the log console command has been given use the command:
awplus(config)#
To remove a filter that sends all messages generated by BGP that have a severity of "notices" or
higher to consoles use the command:
awplus(config)#
To remove a default filter that includes sending critical, alert and emergency level messages to
the console use the command:
awplus(config)#
show log config
Validation
Commands
log console
Related Commands

log email

Configures the device to send log messages to an email address. The email address is specified
in this command. By default no filters are defined for email log targets. Filters must be defined
before messages will be sent.
Syntax
log email <email-address>
Parameter
log
email
<email-address>
Global Configuration mode
Mode
To have log messages emailed to the email address admin@alliedtelesis.com use the command:
Examples
awplus(config)#
show log config
Validation
Commands
default log email
Related Commands
log email
C613-50007-01 REV B
log console msgtext "Bridging initialization"
no log console level notices program bgp
no log console level critical
Description
Logging control
Send log messages to an email address
The email address to send log messages to
log email admin@alliedtelesis.com
Software Reference for SwitchBlade® x908, x900 and x600 Series Switches
TM
AlliedWare Plus
Operating System - Software Version 5.3.1
Logging Commands