IP IRDP MINADVERTINTERVAL

ip irdp minadvertinterval
Overview
This command sets the minimum time allowed between sending router
advertisements from the interface. If you change the minadvertisementinterval
value, also change the lifetime and the maxadvertisementinterval to maintain
the following ratios:
You cannot set the minimum advertisement interval above the maximum interval.
If you are raising the minimum interval to a value above the current maximum
interval, you must change the maximum value first.
The no variant of this command sets the minadvertinterval back to the default of
450 seconds.
ip irdp minadvertinterval <3-1800>
Syntax
no ip irdp minadvertinterval
Default
The IRDP minimum advertisement interval is set to 450 seconds (7.5 minutes) by
default.
Mode
Interface Configuration for a VLAN interface or a local loopback interface.
To set the minimum interval between advertisements on vlan4 to 900 seconds,
Examples
use the following commands:
awplus#
awplus(config)#
awplus(config-if)#
To set the minimum interval between advertisements on vlan4 back to the
default of 450 seconds, use the following commands:
awplus#
awplus(config)#
awplus(config-if)#
C613-50644-01 Rev B
C
OMMANDS
lifetime=3 x maxadvertisementinterval
minadvertisementinterval=0.75 x maxadvertisementinterval
Parameter
Description
<3-1800>
The minimum time between advertisements in seconds.
configure terminal
interface vlan4
configure terminal
interface vlan4
Command Reference for IE220 Series
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ip irdp minadvertinterval 900
no ip irdp minadvertinterval
848