Renesas H8SX/1582 User Manual
Renesas H8SX/1582 User Manual

Renesas H8SX/1582 User Manual

H8sx family / h8sx/1500 series system interface cable

Advertisement

Quick Links

To our customers,
Old Company Name in Catalogs and Other Documents
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website:
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas H8SX/1582

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 H8SX/1582 PLQP0120LA-A User System Interface Cable HS1582ECH61H User’s Manual Renesas Microcomputer Development Environment System H8SX Family / H8SX/1500 Series HS1582ECH61HE Rev.3.00 2008.09...
  • Page 4 Rev. 3.00 Sep. 08, 2008 Page ii of vi REJ10J1396-0300...
  • Page 5 Please be sure to implement safety measures to guard against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a Renesas product, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other applicable measures.
  • Page 6 Rev. 3.00 Sep. 08, 2008 Page iv of vi REJ10J1396-0300...
  • Page 7: Important Information

    Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
  • Page 8: Limited Warranty

    User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas’...
  • Page 9 This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas’ prior written consent.
  • Page 10 • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
  • Page 11 Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
  • Page 12 Rev. 3.00 Sep. 08, 2008 Page VI of VI REJ10J1396-0300...
  • Page 13 Preface The HS1582ECH61H is a user system interface cable that connects an H8SX/1582 E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an PLQP0120LA-A (former package: FP-120B) package for the H8SX/1582 MCU on the user system.
  • Page 14: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System ... 5 2.2.1 Installing IC Socket... 5 2.2.2 Soldering IC Socket ... 6 2.2.3 Inserting Cable Head...
  • Page 15: Section 1 Configuration

    Use an NQPACK120SE-ND socket and an HQPACK120SE cover (manufactured by Tokyo Eletech Corporation) for the PLQP0120LA-A package IC socket on the user system. Figure 1 and table 1 show the external appearance and components, respectively, of the HS1582ECH61H user system interface cable for the PLQP0120LA-A package. To emulator station Screws (M2.0 x 6 mm) Figure 1 HS1582ECH61H User System Interface Cable...
  • Page 16 Section 1 Configuration Table 1 lists the HS1582ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1582ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2.0 x 10 mm) Screws (M2.0 x 6 mm) Guide pins (φ1 mm) Screwdriver Documentation...
  • Page 17: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 18 Section 2 Connection Procedures 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2). E6000H RENESAS HS1527KEPH60H emulator station Figure 2 Example of the HS1527KEPH60H Emulator Station Rev.
  • Page 19: Connecting User System Interface Cable To User System

    Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 20: Soldering Ic Socket

    Section 2 Connection Procedures Use the guide pins provided to determine where to install the IC socket, as shown in figure 3. Pin 1 4 projections to apply epoxy resin adhesive to Bottom view of IC socket Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an PLQP0120LA-A package to the user system.
  • Page 21: Inserting Cable Head

    2.2.3 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an PLQP0120LA-A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4.
  • Page 22 Section 2 Connection Procedures Fasten the user system interface cable head to the IC socket for an PLQP0120LA-A package on the user system with the four screws (M2.0 at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 23: Fastening Cable Body

    Section 2 Connection Procedures 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the unfastening jig Unfastening jig Cable head User system Figure 5 Fastening Cable Body Rev. 3.00 Sep. 08, 2008 Page 9 of 18 REJ10J1396-0300...
  • Page 24: Recommended Dimensions For User System Mount Pad

    Section 2 Connection Procedures Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an PLQP0120LA-A package (NQPACK120SE-ND: manufactured by Tokyo Eletech Corporation). The dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.
  • Page 25: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head Section 2 Connection Procedures 23.0 20.25 63.5 Unit: mm Tolerance: ±0.5 mm Rev.
  • Page 26: Resulting Dimensions After Connecting User System Interface Cable

    Section 2 Connection Procedures Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head User system Figure 8 Resulting Dimensions after Connecting User System Interface Cable Rev.
  • Page 27: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 28 Section 3 Installing the MCU to the User System Screws (M2.0 x 6 mm) User system Figure 9 Installing MCU to User System Rev. 3.00 Sep. 08, 2008 Page 14 of 18 REJ10J1396-0300 Socket cover (HQPACK120SE manufactured by Tokyo Eletech Corporation) Pin 1 IC socket (NQPACK120SE-ND...
  • Page 29: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). 2. Verify the user system interface cable connections by checking the pin states with the CHECK command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1.
  • Page 30 Section 4 Verifying Operation Rev. 3.00 Sep. 08, 2008 Page 16 of 18 REJ10J1396-0300...
  • Page 31: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS1527KEPH60H emulator. Do not use this cable with any other emulator station.
  • Page 32 Section 5 Notice P4 short connector. For details on the differences between the target MCU and the emulator, refer to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges of input voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual. Insert the jumper pin in the P4 short connector so that the higher voltage between AVcc0 and AVcc1 is selected.
  • Page 33 Publication Date: Rev.1.00, June 15, 2004 Rev.3.00, September 8, 2008 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div. Renesas Solutions Corp. © 2008. Renesas Technology Corp., All rights reserved. Printed in Japan.
  • Page 34 Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com RENESAS SALES OFFICES Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
  • Page 36 H8SX/1582 PLQP0120LA-A User System Interface Cable HS1582ECH61H User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10J1396-0300...

This manual is also suitable for:

H8sx/1582 plqp0120la-aHs1582ech61h

Table of Contents