Section 21 Electrical Characteristics
Item
Read data access time 1
Read data access time 2
Read data access time 3
Read data access time 4
Precharge time 1
Precharge time 2
Wait setup time
Wait hold time
Bus request setup time
Bus acknowledge delay
time 1
Bus acknowledge delay
time 2
Bus-floating time
RAS precharge time
CAS precharge time
Low address hold time
RAS delay time 1
RAS delay time 2
CAS delay time 1
CAS delay time 2
WE delay time
CAS pulse width 1
CAS pulse width 2
CAS pulse width 3
Rev. 4.00 Jan 26, 2006 page 728 of 938
REJ09B0276-0400
A
Symbol Min
Max
t
—
2.0 t
ACC1
– 80
t
—
3.0 t
ACC2
– 80
t
—
1.5 t
ACC3
– 80
t
—
2.5 t
ACC4
– 80
t
1.0 t
—
PCH1
cyc
– 30
t
0.5 t
—
PCH2
cyc
– 30
t
40
—
WTS
t
5
—
WTH
t
40
—
BRQS
t
—
50
BACD1
t
—
50
BACD2
t
—
50
BZD
1.5 t
t
—
RP
cyc
– 40
t
0.5 t
—
CP
cyc
– 25
t
0.5 t
—
RAH
cyc
– 25
t
—
50
RAD1
t
—
50
RAD2
t
—
50
CASD1
t
—
50
CASD2
t
—
50
WCD
t
1.5 t
—
CAS1
cyc
– 40
t
1.0 t
—
CAS2
cyc
– 40
t
1.0 t
—
CAS3
cyc
– 40
Condition
B
Min
Max
—
2.0 t
cyc
cyc
– 45
—
3.0 t
cyc
cyc
– 45
—
1.5 t
cyc
cyc
– 45
—
2.5 t
cyc
cyc
– 45
1.0 t
—
cyc
– 20
0.5 t
—
cyc
– 20
25
—
5
—
25
—
—
30
—
30
—
30
1.5 t
—
cyc
– 25
0.5 t
—
cyc
– 15
0.5 t
–
—
cyc
15
—
25
—
30
—
25
—
25
—
25
1.5 t
—
cyc
– 20
1.0 t
—
cyc
– 20
1.0 t
—
cyc
– 20
Test
Unit
Conditions
ns
Figure 21.11,
figure 21.12,
figure 21.14,
ns
figure 21.15,
figure 21.17
ns
ns
ns
ns
ns
Figure 21.13
ns
ns
Figure 21.16
ns
ns
ns
Figure 21.17
ns
to
figure 21.19
ns
ns
ns
ns
ns
ns
ns
ns
ns