Renesas FP-80A User Manual
Renesas FP-80A User Manual

Renesas FP-80A User Manual

User system interface cable for e6000 emulator

Advertisement

Quick Links

To our customers,
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
Old Company Name in Catalogs and Other Documents
Renesas Electronics website:
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas FP-80A

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 H8/3001 FP-80A User System Interface Cable (HS3001ECH61H) for E6000 Emulator User’s Manual...
  • Page 4 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
  • Page 5 H8/3001. The HS3001ECH61H is a user system interface cable that connects an H8/3052 series E6000 emulator (HS3052EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-80A package for the H8/3001 MCU on the user system.
  • Page 6: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...4 Connecting User System Interface Cable to Emulator Station ... 4 Connecting User System Interface Cable to User System ... 6 2.2.1 Installing IC Socket ... 6 2.2.2 Soldering IC Socket ... 6 2.2.3 Inserting Cable Head ...
  • Page 7: Section 1 Configuration

    Section 1 Configuration Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3001ECH61H user system interface cable for the FP-80A package. CAUTION...
  • Page 8 Figure 1 HS3001ECH61H User System Interface Cable...
  • Page 9 Screws (M2.0 x 8 mm) Documentation Quantity Remarks Flat cable For the FP-80A package For installing an FP-80A-packaged MCU For fastening cable head (with four flat washers) For installing an FP-80A-packaged MCU (with four flat washers) User’s manual for HS3001ECH61H (this manual)
  • Page 10: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 11 Figure 2 Connecting User System Interface Cable to Emulator Station...
  • Page 12: Connecting User System Interface Cable To User System

    Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-80A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
  • Page 13: Fastening Cable Head

    2.2.4 Fastening Cable Head 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 14 Fasten the user system interface cable head to the IC socket for an FP-80A package on the user system with the four screws (M2.0 12 mm; with flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 15: Fastening Cable Body

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body...
  • Page 16: Recommended Dimensions For User System Mount Pad

    Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
  • Page 17: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head...
  • Page 18: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable...
  • Page 19: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 20 User system Figure 8 Installing MCU to User System Screws (M2.0 x 8 mm) with flat washers Socket cover Pin 1 mark IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.)
  • Page 21: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. When using the H8/3052 series E6000 emulator (HS3052EPI61H), turn on the emulator according to the procedures described in the H8/300H Series E6000 Emulator User's Manual (HS300HEPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins.
  • Page 22: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.