Timing of Setting of IMFA and IMFB by Input Capture: IMFA and IMFB are set to 1 by an
input capture signal. The TCNT contents are simultaneously transferred to the corresponding
general register. Figure 9.34 shows the timing.
φ
Input capture
signal
IMF
TCNT
GR
IMI
Figure 9.34 Timing of Setting of IMFA and IMFB by Input Capture
N
Rev. 4.00 Jan 26, 2006 page 381 of 938
Section 9 16-Bit Timer
N
REJ09B0276-0400