Renesas H8/3802 User Manual
Renesas H8/3802 User Manual

Renesas H8/3802 User Manual

H8 family/h8/300l super low power series system interface cable for e6000 emulator

Advertisement

Quick Links

To our customers,
Old Company Name in Catalogs and Other Documents
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website:
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas H8/3802

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 H8/3802 Group FP-64A User System Interface Cable for E6000 Emulator User’s Manual H8/3802 HS3802ECH61HE Renesas Microcomputer Development Environment System H8 Family/H8/300L Super Low Power Series Rev.3.0 2003.12...
  • Page 4 6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in whole or in part these materials. 7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination.
  • Page 5: Important Information

    Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
  • Page 6: Limited Warranty

    User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas's warranty.
  • Page 7 This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas's prior written consent.
  • Page 8 • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
  • Page 9 Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
  • Page 10 Thank you for purchasing this user system interface cable (HS3802ECH61H) for the Renesas’s original microcomputer H8/3802, H8/38004 group. The HS3802ECH61H is a user system interface cable that connects an H8/3802, H8/38004 group E6000 emulator (HS3800EPI60H; hereinafter referred to as the emulator) to the IC socket for a...
  • Page 11: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System... 5 2.2.1 Installing IC Socket... 5 2.2.2 Soldering IC Socket ... 5 Inserting Cable Head... 6 2.2.3 2.2.4 Fastening Cable Head ...
  • Page 12: Section 1 Configuration

    Section 1 Configuration Use an IC149-064-008-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package IC socket on the user system. Figure 1 shows the configuration of the HS3802ECH61H user system interface cable for the FP-64A package. To emulator station Screws (M2 x 8 mm) with flat washers Figure 1 HS3802ECH62H User System Interface Cable...
  • Page 13 Table 1 lists the HS3802ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3802ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2 x 12 mm) Screws (M2 x 8 mm) Documentation Quantity Remarks...
  • Page 14: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 15 Emulator station Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station...
  • Page 16: Connecting User System Interface Cable To User System

    Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 17: Inserting Cable Head

    2.2.3 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
  • Page 18 Fasten the user system interface cable head to the IC socket for an FP-64A package on the user system with the four screws (M2 tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 19: Fastening Cable Body

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jigs. Remove jig Cable head User system Figure 4 Fastening Cable Body...
  • Page 20: Recommended Dimensions For User System Mount Pad

    Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
  • Page 21: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. 28.0 17.8 63.5 Unit: mm Tolerance: ±0.5 mm Figure 6 Dimensions for User System Interface Cable Head...
  • Page 22: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head User system Figure 7 Resulting Dimensions after Connecting User System Interface Cable IC socket (IC149-064-008-B5 manufactured by...
  • Page 23: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 24 Screws (M2 x 8 mm) with flat washers User system Figure 8 Installing MCU to User System Socket cover Pin 1 IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.)
  • Page 25: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. When using the H8/3802 group E6000 emulator (HS3800EPI60H), turn on the emulator according to the procedures described in the H8/3802 Group E6000 Emulator User's Manual (HS3800EPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
  • Page 26 Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. R1 1 M HCU04 To E6000 emulator HCU04 R2 270 OSC1 OSC2 System clock oscillator Figure 9 System Clock Oscillator and Subclock Input Specifications 5.0 V 4.0 V 1.35 V...
  • Page 27: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.
  • Page 28 Figure 11 P1 Short Connector...
  • Page 29 E6000 Emulator User's Manual Publication Date: Rev.3.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2003 Renesas Technology Corp. All rights reserved. Printed in Japan.
  • Page 30 H8/3802 Group FP-64A User System Interface Cable for E6000 Emulator User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10B0098-0300H...

This manual is also suitable for:

Hs3802ech61he

Table of Contents