H3C MSR 20-20 Command Reference Manual page 384

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

384
C
22: F
R
HAPTER
RAME
Related command:
Example
C
C
ELAY
ONFIGURATION
OMMANDS
If you do not specify the name argument, this command displays the information
of all the X.25 templates.
x25 template, x25-template.
# Display the configuration of the X.25 template named "vofr".
<Sysname> display x25 template vofr
Template:vofr
X25 parameters
X121 address:none
Timers
Idle:0 (second)
Channels
Incoming-only:disable
Window size
In:2
Out:2
Packet size
In:128
Out:128
LAPB parameters
Modulo:8
K:7
Timers
T1:3000
Table 52 Description on t he fields of the display x25 template command
Field
X25 parameters
X121 address
Modulo
Timers
Channels
Window size
Packet size
LAPB parameters
Modulo
N1
N2
Timers
Modulo:8
T10/T20:1
T11/T21:200
Two-way:1-1024
N1:12056
N2:10
T2:1500
T3:0
Description
X.25-related settings
X.121 address
Window modulo, which defaults to 8.
Idle: Maximum idle period of SVCs
T10/T20: Delay of the re-start/re-transmission timer
T11/T21: Delay of the call request transmission timer
T12/T22: Delay of the reset request transmission timer
T13/T23: Delay of the clear request transmission timer
Incoming-only: Channel range of incoming-only calls
Two-way: Two-way channel range
Outgoing-only: Channel range of outgoing-only calls
In: Receiving window size
Out: Transmitting window size
In: Maximum X.25 packet size allowed for receiving
Out: Maximum X.25 packet size allowed for transmitting
LAPB-related settings
Modulo for numbering LAPB frames
Maximum packet size (in bytes) a DCE/DTE allows
Maximum number of retries allowed for an DTE/DCE to transmit
a packet
T1: Transmission timer
T2: Receiving timer
T3: Idle channel timer
T12/T22:180
T13/T23:180
Outgoing-only:disable

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msr 20-21Msr 30-16Msr 30-20Msr 30-40Msr 30-60Msr 50 ... Show all