Fe1 Timeslot-List - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

View
Parameter
Description
Example

fe1 timeslot-list

Syntax
View
Parameter
Description
undo fe1 loopback
E1-F interface view
local: Sets the interface in internal loopback mode.
payload: Sets the interface in external payload loopback mode.
remote: Sets the interface in external loopback mode.
Use the
fe1 loopback
Use the
undo fe1 loopback
By default, loopback is disabled.
Loopback is intended for checking the condition of interfaces or cables. Disable it
otherwise.
n
The three loopback modes cannot be used at the same time on an E1-F interface.
# Set interface Serial 2/0 in internal loopback mode.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] fe1 loopback local
fe1 timeslot-list list
undo fe1 timeslot-list
E1-F interface view
list: Specifies timeslots to be bundled. They are numbered 1 through 31. You may
specify a single timeslot by specifying its number, a range of timeslots by
specifying a range in the form of number1-number2, or several discrete timeslots
by specifying number1, number2-number3.
Use the
fe1 timeslot-list
Use the
undo fe1 timeslot-list
By default, all the timeslots on the E1-F interface are bundled to form a 1984 kbps
interface.
Timeslot bundling results in interface rate change. For example, after you bundle
timeslots 1 through 10 on the interface, the interface rate becomes 10 × 64 kbps.
command to set the E1-F interface in a loopback mode.
command to restore the default.
command to bundle timeslots on the E1-F interface.
command to restore the default.
235

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msr 20-21Msr 30-16Msr 30-20Msr 30-40Msr 30-60Msr 50 ... Show all