Fe1 Code; Fe1 Detect-Ais - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

View
Parameter
Description
Example

fe1 code

Syntax
View
Parameter
Description
Example

fe1 detect-ais

Syntax
undo fe1 clock
E1-F interface view
master: Adopts the internal clock as the clock source.
slave: Adopts the line clock as the clock source.
Use the
command to configure clock source for the E1-F interface.
fe1 clock
Use the
undo fe1 clock
When the E1-F interface is working as DCE, choose the internal clock (master) for
it. When it is working as DTE, choose the line clock for it.
# Use the internal clock as the clock source on E1-F interface Serial 2/0.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] fe1 clock master
fe1 code { ami | hdb3 }
undo fe1 code
E1-F interface view
ami: Adopts AMI line code format.
hdb3: Adopts HDB3 line code format.
Use the
command to set the line code format for the E1-F interface.
fe1 code
Use the
undo fe1 code
Keep the line code format of the interface in consistency with that used by the
remote device.
# Set the line code format of interface Serial 2/0 to AMI.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] fe1 code ami
fe1 detect-ais
command to restore the default, that is, line clock.
command to restore the default, that is, HDB3.
233

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msr 20-21Msr 30-16Msr 30-20Msr 30-40Msr 30-60Msr 50 ... Show all

Table of Contents