358
C
21: B
HAPTER
ASIC

llc2 timer reject

Syntax
View
Parameter
Description
Example

reset dlsw circuits

Syntax
View
Parameter
Description
Example

reset dlsw reachable-cache

Syntax
View
DLS
C
C
W
ONFIGURATION
OMMANDS
llc2 timer reject mseconds
undo llc2 timer reject
Ethernet interface view
mseconds: LLC2 REJ status time in milliseconds. The effective range is 1 to 60,000.
Use the
llc2 timer reject
namely the amount of time the router waits for the expected frame after it
receives an unexpected frame and sends a reject frame.
Use the
undo llc2 timer reject
By default, the LLC2 REJ status time is 500 milliseconds.
# Set the LLC2 REJ time to 2, 000 milliseconds on Ethernet 1/0.
<Sysname> system-view
[Sysname] interface ethernet 1/0
[Sysname-Ethernet1/0] llc2 timer reject 2000
reset dlsw circuits [ circuit-id ]
User view
circuit-id: DLSw virtual circuit ID, in the range of 0 to 0xFFFFFFFF.
Use the
reset dlsw circuits
Note that this command without circuit-id clears the information of all DLSw
virtual circuits; otherwise, this command clears the information of the specified
virtual circuit.
# Clear the information of virtual circuit 100.
<Sysname> reset dlsw circuits 100
reset dlsw reachable-cache
User view
command to configure the LLC2 REJ status time,
command to restore the default setting.
command to clear DLSw virtual circuit information.