Oam Ais-Rdi - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

304
C
19: ATM C
HAPTER
Example

oam ais-rdi

Syntax
View
Parameter
Description
Example
C
ONFIGURATION
OMMANDS
mechanism used by PVC is FIFO. You can use the fifo queue-length command in
the PVC view to change its queue length.
n
The effect of this command applies to ATM main interface and sub-interface
simultaneously.
# Set the MTU of ATM interface atm 1/0 to 1492 bytes.
<Sysname> system-view
[Sysname] interface atm 1/0
[Sysname-Atm1/0] mtu 1492
oam ais-rdi up up-count down down-count
undo oam ais-rdi
PVC view, ATM class view
up-count: Period (in seconds). A PVC goes up if no alarm indication signal/remote
defect indication (AIS/RDI) alarm cell is received in the period specified by this
argument. The value range of this argument varies with device model.
down-count: Number of AIS/RDI alarm cells. A PVC goes down if the number of
the successive AIS/RDI alarm cells received reaches the number specified by this
argument. The value range of this argument varies with device model.
Use the
oam ais-rdi
cell detection.
Use the
undo oam ais-rdi
By default, AIS/RDI alarm cell detection is enabled, which means a PVC goes down
if the number of successive AIS/RDI alarm cells received reaches that specified by
the down-count argument, and it goes up if no AIS/RDI alarm cell is received in a
period specified by the up-count argument.
Note that the oam ais-rdi command is not applicable to the secondary PVCs of a
PVC group.
n
The primary PVC of a PVC group is the PVC based on which the PVC group is
created.
Second PVCs are created in PVC groups.
# Configure the AIS/RDI alarm detection parameters for PVC 1/32, setting both
up-count and down-count to 5.
<Sysname> system-view
[Sysname] interface atm 1/0
[Sysname-Atm1/0] pvc 1/32
[Sysname-atm-pvc-Atm1/0-1/32] oam ais-rdi up 5 down 5
command to modify the parameters related to AIS/RDI alarm
command to restore the default.