H3C MSR 20-20 Command Reference Manual page 272

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

272
C
17: F
HAPTER
UNDAMENTAL
CT3 I
C
NTERFACE
ONFIGURATION
Table 21 Description on the fields of the display controller t3 command
Field
Data in current interval:
Line Code Violations
Far End Block Error
C-Bit Coding Violation
P-bit Coding Violation
Framing Bit Err
Severely Err Framing Secs
C-bit Err Secs
C-bit Severely Err Secs
P-bit Err Secs
P-bit Severely Err Secs
Unavailable Secs
Line Err Secs
Data in Interval 1
Total Data (last 17 15 minute
intervals)
T3 2/0 CT1 1 is up
Frame-format ESF, clock slave,
loopback not set
FDL Performance Report is disabled
Transmitter is sending RAI
Receiver alarm state is LOF
Line loop back activate code using
inband signal last sent
BERT state
Test pattern
Status
Sync Detected
Time
Time past
Bit errors (since test started)
Bits received (since test started)
Bit errors (since latest sync)
C
OMMANDS
Description
Statistics spanning the current 15-minute interval,
coving the counts of these items:
Line code violations: BPV, or EXZ
Far-end block error
C-bit coding violation
P-bit coding violation
Framing bit error
C-bit erroneous second
C-bit severely erroneous second, that is, the second
during which 44 C-bit errors occur
P-bit erroneous second
P-bit severely erroneous second, that is, the second
during which 44 P-bit errors occur
Service unavailable second
Line erroneous second, during which LOS, BPV, EXZ,
C-bit, P-bit, and other errors occur
Data in interval 1
Total data spanning the last 17 intervals
State of T1 line on the CT3 interface: up or down. In
this output sample, T1 line 1 is up.
Information about the T1 line:
Framing format-ESF or SF
Clock source-slave for the line clock and master for the
internal clock
Loopback-Local, remote, payload, or not set
Transmission of PPR in the FDL is disabled. You may
enable that with the t1 set fdl ansi command.
The transmitter of the T1 line is sending RAI signals.
When the T1 line receives LOS, LOF, or AIS signals, it
sends RAI signals.
The type of alarm signal that the T1 line can receive:
LOS, LOF, AIS, or RAI
The loopback code sent last time is in-band LLB
activation request code.
BERT test state: running, complete, or stopped (not
completed)
Test pattern in use, 2^11 in this sample output;
synchronization state, and the number of detected
synchronizations
The duration of the BERT test and the time that has
elapsed
Number of bit errors received since the start of the
BERT test
Number of bits received since the start of the BERT test
Number of bit errors received since the last
synchronization

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msr 20-21Msr 30-16Msr 30-20Msr 30-40Msr 30-60Msr 50 ... Show all

Table of Contents